Tektronix A6302 Current Probe
|
|
| |
|
Tektronix A622 AC/DC Clamp-on Current Probe
|
|
| |
|
Agilent E5346A Mictor Probe
|
|
| |
|
Tektronix P7380 Differential Probe 8GHz
|
|
| |
|
Agilent N1020A TDR Probe
|
|
| |
|
Agilent 1130A 1.5 GHz Differential Probe
|
|
| |
|
Agilent E2675A Differential Browser Kit for Infiniimax Probes
|
|
| |
|
Tektronix 1103 Probe Power Supply
|
|
| |
|
Tektronix P6247 Differential Probe, 1 GHz
|
|
| |
|
Tektronix P6248 Differential Probe, 1.5 GHz
|
|
| |
|
Tektronix AM503 Current Probe Amplifier
|
|
| |
|
Tektronix A6302 Probe
|
|
| |
|
Tektronix A6302XL Probe
|
|
| |
|
Tektronix A6303XL Probe
|
Tektronix A6303XL Probe
Features: • 8 Meter Cable • 100 Amps Continuous / 500 Amps Peak • DC to 10 MHz
For pricing information, or to receive an official price quotation for the Tektronix A6303XL Probe, please click on the "Request Quote" button.
|
| |
|
Tektronix A6312 Probe
|
|
| |
|
Fluke i2000 AC Current Probe
|
|
| |
|
Fluke i1000 AC Current Probe
|
|
| |
|
Agilent 34134A DC Coupled Current Probe
|
Agilent 34134A DC Coupled Current Probe
The Agilent 34134A is a clamp-on probe for a wide range of applications such as measuring ground currents, powers ripple or current distribution in systems.
Features: • Termination: right angle shrouded banana plugs • Frequency range: dc to 8 kHz • Current range, 10 mA to 80 A dc, 10 mA to 60 A ac • Accuracy: 2% reading +5 mA (1 V/A range) • Output signals: 1 V/A and 10 mA • Length: 1.5 meters • Minimum input resistance of DMM: 100 kOhm • Rating: 600 V CAT III
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Agilent 34134A DC Coupled Current Probe, please click on the "Request Quote" button below. |
| |
Product Data Sheets
|
Agilent 34134A DC Coupled Current Probe Data Sheet
|
| |
| |
|
Tektronix TDP1500 Differential Probe, 1.5 GHz
|
Tektronix TDP1500 Differential Probe, 1.5 GHz
Outstanding Electrical Performance • 1.5 GHz Bandwidth Models – Accurate Measurements for Serial and Digital Applications • Excellent Common Mode Rejection – Reduces Measurement Errors in Higher Common Environments • Low Capacitive and Resistive Loading – Maintains Signal Fidelity and Reduces DC Biasing Interactions Versatile Mechanical Performance • Compact Probe Head Size for Probing Small Geometry Circuit Elements • DUT Attachment Accessories Enable Connection to Fine-spaced SMDs • Robust Design for Reliability Easy to Use • Connects Directly to DPO7000, DPO4000, and MSO4000 Series Oscilloscopes Using TekVPI Probe Interface • Provides Automatic Units Scaling and Readout on the Oscilloscopes Display • Easy Access to Probe Comp Box Controls or Oscilloscope Probe Menu Display for Probe Status, Setup Control, and Diagnostic Information Integrated Scope/Probe System • Direct Connection to and Powered from TekVPI™ Oscilloscope Interface (Connects directly to TekVPI scopes without the need of an external power supply, like many competitors require) • Single-button Oscilloscope Probe Menu Access • Setup and Control from Probe Comp Box or Oscilloscope User Interface • AutoZero - Zeros Out Output Offset • Remote GPIB/USB Probe Control Through the Oscilloscope (Requires TEK-USB-488 Adapter for GPIB control on DPO4000 and MSO4000)
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Tektronix TDP1500 Differential Probe, 1.5 GHz, please click on the "Request Quote" button below.
|
| |
Product Data Sheets
|
Tektronix TDP1500, TDP3500 Differential Probes Data Sheet
|
| |
| |
|
Tektronix TDP3500 Differential Probe, 3.5 GHz
|
Tektronix TDP3500 Differential Probe, 3.5 GHz
Outstanding Electrical Performance • 1.5 GHz Bandwidth Models – Accurate Measurements for Serial and Digital Applications • Excellent Common Mode Rejection – Reduces Measurement Errors in Higher Common Environments • Low Capacitive and Resistive Loading – Maintains Signal Fidelity and Reduces DC Biasing Interactions Versatile Mechanical Performance • Compact Probe Head Size for Probing Small Geometry Circuit Elements • DUT Attachment Accessories Enable Connection to Fine-spaced SMDs • Robust Design for Reliability Easy to Use • Connects Directly to DPO7000, DPO4000, and MSO4000 Series Oscilloscopes Using TekVPI Probe Interface • Provides Automatic Units Scaling and Readout on the Oscilloscopes Display • Easy Access to Probe Comp Box Controls or Oscilloscope Probe Menu Display for Probe Status, Setup Control, and Diagnostic Information Integrated Scope/Probe System • Direct Connection to and Powered from TekVPI™ Oscilloscope Interface (Connects directly to TekVPI scopes without the need of an external power supply, like many competitors require) • Single-button Oscilloscope Probe Menu Access • Setup and Control from Probe Comp Box or Oscilloscope User Interface • AutoZero - Zeros Out Output Offset • Remote GPIB/USB Probe Control Through the Oscilloscope (Requires TEK-USB-488 Adapter for GPIB control on DPO4000 and MSO4000)
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Tektronix TDP3500 Differential Probe, 3.5 GHz, please click on the "Request Quote" button below.
|
| |
Product Data Sheets
|
Tektronix TDP1500, TDP3500 Differential Probes Data Sheet
|
| |
| |
|
Agilent 85024A High-Frequency Probe, 300 kHz to 3 GHz
|
Agilent 85024A High-Frequency Probe, 300 kHz to 3 GHz
The Agilent 85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of Agilent RF analyzers.
Features: • Easy to perform in-circuit measurements • Excellent frequency response and unity gain • High probe sensitivity • Low distortion levels
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Agilent 85024A High-Frequency Probe, 300 kHz to 3 GHz, please click on the "Request Quote" button below.
|
| |
Product Data Sheets
|
Agilent 85024A High Frequency Probe Data Sheet
|
| |
| |
|
Agilent 11945A Close-Field Probe Set, 9 kHz to 1 GHz
|
Agilent 11945A Close-Field Probe Set, 9 kHz to 1 GHz
The Agilent 11945A close-field probe set includes both the 11940A and 11941A probes to provide full coverage from 9 kHz to 1 GHz. This set provides a powerful measurement tool for electrical and mechanical designers who want to search for and eliminate sources of interference from their products early in the design process. Option E51 adds the Agilent 11909A preamplifier, a 36 inch (914 mm) Type-N cable and a carrying bag to store and protect the entire set of probes, preamplifier, and cables.
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Agilent 11945A Close-Field Probe Set, 9 kHz to 1 GHz, please click on the "Request Quote" button below.
|
| |
Product Data Sheets
|
Agilent 11945A Close-Field Probe Set Data Sheet
|
| |
| |
|
Tektronix TCP202 DC Coupled Current Probe
|
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for the Agilent 81636B Fast Optical Power Sensor, please click on the "Request Quote" button below. |
| |
|
Agilent 41941A Impedance Probe Kit
|
HP Agilent 41941A Impedance Probe Kit
The HP 41941A/B will perform reliable impedance evaluations up to 100 MHz. It can be used as a grounded probe to evaluate the impedance of in-circuit components such as printed circuit patterns, and the input/output impedance of circuits. In addition, you can perform DC biased measurements up to +/-150 V/0.5 A, to measure the DC characteristics of inductors, capacitors, materials, and semiconductors. Measurement range: 100 MO to 1 MO. Used with the 4194A Impedance/Gain-Phase Analyzer |
| |
|
Hameg HZ540/HZ550 Probe set
|
Hameg HZ540/HZ550 Probe set
The HZ540/550 are the ideal toolkits for the investigation of RF electromagnetic fields. They are indispensable for EMI pre-compliance testing during product development, prior to third party testing. The sets include 3 or 5 hand-held probes with built-in preamplifier covering the frequency range from <1 MHz to approx. 3000 MHz.
The probes of the basic set HZ540 include one magnetic field probe, one electric field probe, and a high impedance probe. In addition to the HZ550 features an optional μmagnetic field probe and an antenna. All probe outputs are matched to the 50 Ω inputs of spectrum analyzers or RF receivers.
Additional technical information is available by downloading the .pdf data sheet below.
For pricing information, or to receive an official price quotation for Hameg HZ540/HZ550 Probe set, please click on the "Request Quote" button below. |
| |
Product Data Sheets
|
HAMEG HZ540, HZ550 EMV Near-Field Probe Data Sheet
|
| |
| |